Inquiry For Liaison Service
Sector abcHealth Services/EquipmentsTender ValueN.A.
LocationDelhi - India Ref.No39283262
Closing Date03 - Aug - 2020
Procurement of various anaesthesia consumable items - i.v. cannula 24 g thin walled small hub, without wings or injection port, good quality, non - thrombogenic material, i.v. cannula 22 g, small hub, without wings or injection port, good quality, thin walled, non - thrombogenic material, i.v. cannula 20 g, small hub, without wings or injection port, good quality, thin walled, non - thrombogenic material, i.v. cannula 18 g, small hub, without wings or injection port, good quality, thin walled, non - thrombogenic material, i.v. cannula 16 g, small hub, without wings or injection port, good quality, thin walled, non - thrombogenic material, i.v. cannula 14 g, small hub, without wings or injection port, good quality, thin walled, non - thrombogenic material, i.v. cannula 24 g small hub, without wings or injection port, good quality thin walled, non - thrombogenic material, in protective sleeve or device to prevent needle stick injuries., i.v. cannula 22 g, small hub, without wings or injection port, good quality thin walled, non - thrombogenic material, in protective sleeve or device to prevent needle stick injuries., i.v. cannula 20 g, small hub, without wings or injection port, good quality thin walled, non - thrombogenic material, in protective sleeve or device to prevent needle stick injuries., i.v. cannula 18 g, small hub, without wings or injection port, good quality thin walled, non - thrombogenic material, in protective sleeve or device to prevent needle stick injuries., i.v. cannula 16 g, small hub, without wings or injection port, good quality thin walled, non - thrombogenic material, in protective sleeve or device to prevent needle stick injuries., i.v. cannula 14 g, small hub, without wings or injection port, good quality thin walled, non - thrombogenic material, in protective sleeve or device to prevent needle stick injuries., pressure monitoring lines 200 cm long, good quality tubing, leak proof, should withstand high pressures, luer lock at both ends. dead space 1.5-2 ml, male-to-male connector with luer lock at both ends., catheter mount-with swivel end, (both ends) and port for suction and fibre optic bronchoscope 32mm female end for connecting the breathing circuit, paediatric breathing circuit (mapleson) with breathing bag and swivel end to fit endotracheal tube, light weight, a valve at the tail end of the bag, t-connector for intravenous set. should have luer lock and injection cap and a clamp, should be of high quality material., transducer domes (disposable) with flushing device to fit existing reusable transducers having range 0-300, fast zeroing and on line calibration facility, air should be easily removable, three way stop cocks. luer lock and free movement of the tap, no leaks, and should fit the extension lines and cannulae snugly without difficulty., mapleson "c" circuit with breathing bag, connectors and breathing valve, disposable anaesthesia close circuits to fit soda lime canister, plastic, light weight 1.5m (stretched length) long, adult, disposable anaesthesia close circuits to fit soda lime canister, plastic, light weight 1.0-1.5 m long, paediatric, triple lumen catheter (7f) (adult) 15 to 20cm long 3 lumens of size 16g 18g. 18g should have good quality puncture needle, j-tip guide wire and a dilator. should have good fixation device, preferably contain a blade and a skin suture, should have mechanism for easy insertion of guide wire., triple lumen paediatrics cvc 5.5 fr. 8 to10 cm longh should have thin walled (good qulaity) puncture needle, good fixation, should have mechanism for easy insertion. j tip guide wire with 2 dilators, prefaerably contain a blade., paediatric triple lumen central venous catheter 4.5 fr., 8 cms length with 1 echogenic introducer needle 21 g, 1 shour iv cannulae 22g, j guidewire with easy insertion mechanism, 2 dilators good secondary fixation wing injection caps scalpel., quad lumen catheter (adult) 15 to 20cm long 4 (quad) lumens of size 14g, 16g, 16g, 18g should have good quality puncture needle, j-tip guide wire and a dilator. should have good fixation device, preferably contain a blade and a skin suture, should have mechanism for easy insertion of guide wire., central venous catheter 18g iwht cannulae/needle insertion technique 45 cms long in protected plastic sleeve with a plastic stillete., peripherally inserted central venous catheter with a 14 g introducer cannulae over stillete. 70 cms ( with markings) long catheter in protechted plastic sleeve with marking with a plastic stillete., central venous catheter 20g, with cannula/needle (18g) insertion technique 30cm long in protected plastic sleeve with a plastic stillete, ecg electrodes (adult) should stick well, do not detach with surgical preparation and draping. should give good quality ecg signal., ecg electrodes (paediatric).should stick well, not detach with surgical preparation and draping. should give good quality ecg signal., sterile draping sheet for cannulation of internal ju
If you are a new user, then please register, it's Free and then fill the form below.

If you are registered with us, just fill the form below, we will get back to you shortly.


All fileds marked with '*' are compulsary.
Email Id : *
Comments: *
 Login/Register
Members/Visitors Login to continue
 Email Id:
 Password:


 Forgot Password?
 Tenders by Ownership
Central Government/Public Sector Tenders
Co-operatives Tenders
Corporations/ Associations/ Others Tenders
Education & Research Institutes Tenders
Joint Sector Tenders
Non classified Tenders
Private Sector Tenders
Research Institutes Tenders
State Government Tenders
Trust Tenders